Filter Results By:

Products

Applications

Manufacturers

Data Acquisition

senses the physical, represented as an analog signal, that is then converted to digital data. AKA: DAQ

See Also: Data Acquisition Systems, PCI Data Acquisition, DAQ, Digitizers


Showing results: 1201 - 1215 of 1540 items found.

  • Booster and In-line Amplifier

    Amonics Ltd.

    Amonics' EDFA range adopts unique design to produce maximum signal gain and saturated output power while maintaining low noise figure, enabling test capabilities in system or component level manufacturing and characterizing processes, as well as facilitating highly demanding R&D applications. The compact turnkey benchtop or 19" rackmount unit incorporates a user-friendly front panel housing with a LCD monitor display, key switch, power control knob and optical connectors. An integrated RS232 computer interface enables easy control, diagnostic functions and data acquisition.

  • Rugged COTS Systems

    North Atlantic Industries

    NAI’s family of highly configurable Rugged COTS Systems are ideally suited for defense, commercial aerospace, and industrial applications that require high-density I/O, communications, Ethernet switching, and processing for mission-critical tasks such as communications, guidance, sense and response, data acquisition and motion control. The simplified, modular approach of our Configurable Open Systems Architecture™ (COSA®) enables us to use the same building blocks across multiple platforms and programs, making it possible for you to develop semi-custom solutions quickly, without NRE, while retaining all the benefits of COTS products.

  • MicroTCA Systems

    pixus technologies

    Pixus Technologies offers customized MicroTCA® shelves and system solutions. With expertise in xTCA systems, along with backplane and cooling specialists, Pixus will help you create a winning µTCA design. MicroTCA is a modular, open standard for building high performance switched fabric computer systems in a small form factor. MicroTCA systems utilize standard Advanced Mezzanine Cards (AMCs) which provide processing and I/O functions. MicroTCA targets smaller telecom systems at the edge of the network, as well as mobile, military, telemetry, data acquisition, and avionics applications.

  • 128 Channel Digital I/O Modular PXI Card

    GX5733 Series - Marvin Test Solutions, Inc.

    The GX5733 is a 3U modular digital I/O card that offers up to 128 I/O channels. Designed for ATE, data acquisition, or process control systems where a large number of discrete I/O channels are required, the GX5733 offers the highest channel density and flexibility in the industry for a single-slot, 3U PXI plug-in board. 96 channels support TTL levels and an additional 32 I/O channels can be customized by installing one of Marvin Test Solutions' GX57xx series I/O modules. Alternatively, the remaining port can be configured to support 32 TTL channels.

  • DCA Equivalent-time Sampling Oscilloscopes

    Keysight Technologies

    Equivalent-time (sampling) oscilloscopes are also known as digital communication analyzers (DCA). They are designed to visualize and analyze the analog properties of high-speed signals used in data center and wireline telecom applications. The Keysight DCA platform features a wide variety of optical, electrical, and TDR/TDT modules, compliance applications, and a common FlexDCA user interface to ensure more efficient testing in both R&D and manufacturing. Due to an ultra-low jitter and low-noise acquisition system, the Keysight DCA series provides industry-leading measurement accuracy for high-speed digital designs including 400G/800G Ethernet and Fibre Channel.

  • sbRIO-9227, Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module

    781118-01 - NI

    Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The sbRIO‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the sbRIO‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics. Non-enclosed modules are designed for OEM applications.

  • C Series PROFINET Interface Module

    NI

    The C Series PROFINET Interface Module provides two PROFINET interface ports that enable you to reliably connect programmable logic controllers (PLCs), I/O, sensors, and drives over long distances in industrial environments. PROFINET is an application protocol that uses familiar concepts from PROFIBUS that are implemented on the physical layer of Ethernet. The C Series PROFINET Interface Module includes NI-PROFINET driver software for human machine interface (HMI) and supervisory control and data acquisition (SCADA) applications. You can perform PROFINET device automated test using these interfaces.

  • UV Fluorescence Hydrogen Sulfide Analyzer

    Model T101 - Teledyne Monitor Labs

    The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T101 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ S​oftware. ​​

  • FPGA Mezzanine Card

    FMC432 - Sundance Multiprocessor Technology Ltd.

    The FMC432 is a dual 10 Gigabit Ethernet (10GBASE-T) FPGA Mezzanine Card with two RJ45 connectors available on the front panel. Compliant with the VITA 57.1 standard the FMC432 is compatible with FPGA carrier cards offering High Pin Count connectors. It also allows for the option to stack an additional FMC over it. Any of the 4DSP FMC that use LVDS and single ended signaling only can be mounted over the FMC432, thus offering users with the ability to build a complete high speed data acquisition, waveform generation and communication solution while using a single FMC site on an FPGA carrier card.

  • Software

    FDCS - Mesuro Ltd

    Beyond traditional Noise and Harmonic Load/Source Pull, FDCS also supports Tuner and Fixture (TRL) calibrations, Time Domain Load Line acquisition, Pulsed IV and Load Pull and Active feedback Power Injection operations (for Γ ≥ 1).The measured data are processed graphically into 2D and 3D plots and are converted into popular simulator formats (ADS, AWR etc.).The FDCS user unterface includes many many improvements and optimizations to make load pull and noise measurement easier.The software has ActiveX control for controlling MPT tuners in any ActiveX compatible platform.

  • Software

    Focus Microwaves

    Beyond traditional Noise and Harmonic Load/Source Pull, FDCS also supports Tuner and Fixture (TRL) calibrations, Time Domain Load Line acquisition, Pulsed IV and Load Pull and Active feedback Power Injection operations (for Γ ≥ 1).The measured data are processed graphically into 2D and 3D plots and are converted into popular simulator formats (ADS, AWR etc.).The FDCS user unterface includes many many improvements and optimizations to make load pull and noise measurement easier.The software has ActiveX control for controlling MPT tuners in any ActiveX compatible platform.

  • Source Measure Units

    NGU - Rohde & Schwarz GmbH & Co. KG

    Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.

  • Spectroscopic Reflectometer

    Nano-View Co. Ltd.

    – Antireflective coating (ARC) on textured (poly-) crystalline silicon solar cellMeasurement– Thickness, Reflectivity, n&kWavelength– 420 – 950 nm (1.3-3.0 eV) : expandableAccuracy (thickness measurement on specular sample)– 104.5 nm for 104.8 nm SiO₂on c-Si* Accuracy can be dependent on the quality of filmThickness range– 10 nm ~ 20 mm (depend on sample)Data acquisition time– < 1 sBeam spot size– ~ 50 mmFocusing of beam– Manual (optional auto-focus)Sample stage– Manual X-Y stage (specify sample size and travel distance)(optional automatic X-Y stage for mapping)

  • Compact Measurement System For Steel Wire And Rods With Small Diameters

    LAP GmbH

    A glowing hot wire is pulled through the rolling mill at about 120 meters per second during ongoing production. Speed, high temperatures and dirt are special challenges for a high-precision measuring system. Our solution is the Contour Check Wire. It is specially designed for the geometric measurement of wires, rods and rebar and, at 800 Hz, offers the optimum measuring rate for accurate data acquisition. In the uniaxial version, you can check the diameter; in the two- to three-axis version, the ovality can also be determined. The small dimensions and light weight allow a quick and easy integration of the Contour Check Wire into the existing line.

  • Multiphoton Laser Scanning Microscope

    FVMPE-RS - Olympus Corp.

    The Olympus FVMPE-RS multiphoton imaging system is purpose-built for deep imaging in biological tissue, aimed at revealing both detail and dynamics. Innovative features for efficient delivery and detection of photons in scattering media enable high signal-to-noise ratio acquisition. This translates to bright images with precise details — even from deep within the specimen. High sensitivity is matched with high-speed imaging to capture rapid in vivo responses. For advanced applications, dual-wavelength excitation extending to 1300 nm is available. Independent control of visible or multiphoton laser light stimulation and the ability to synchronize with patch clamp data are also possible.

Get Help